PLM 20K44

產品規格

Max output power (all channels driven)1

2 ohms

4400 W

2.67 ohms

5000 W

4 ohms

4400 W

8 ohms

2300 W

16 ohms

1150 W

Hi-Z 70 V

3300 W

Hi-Z 100 V

4700 W

Max output power single channel1

2 ohms

4400 W

2.67 ohms

5900 W

4 ohms

4600 W

8 ohms

2300 W

16 ohms

1150 W

Hi-Z 70 V

3300 W

Hi-Z 100 V

4700 W

Amplifier output modules (all models, all channels)

Peak output voltage

194 V

Max. output current

67 A

Rational Power Management (RPM)

Regardless of model, any channel has potential to deliver the max single channel output power

Default voltage limitation (can be lifted with RPM configuration)

194 V

Protection features

Current Average Limiter (CAL), Very High Frequency Protection (VHF), Direct Current Protection (DC), Short Circuit Protection, Current-Clip Limiter, Voltage Clip Limiter, Temperature protection

Audio Performance (Amplifier platform with digital input)

THD + N 20 Hz - 20 kHz for 1 W

< 0.05 %

THD + N at 1 kHz and 1 dB below clipping

< 0.04 %

Dynamic range

> 114 dB

Channel separation (Crosstalk) at 1 kHz

> 70 dB

Frequency response (1 W into 8 Ohm, 20 Hz - 20 kHz)

+/- 0.05 dB

Internal Sample Rate / Data path

48 / 96 kHz / 32 bit floating point

Product propagation delay AES 96 kHz / analog input

1.61 / 1.68 ms

AES Inputs

Inputs

4 AES inputs

Supported sample rates / resolution

44.1, 48, 88.2, 96, 176.4, 192 kHz / up to 24 bits

Sample rate conversion THD+N 20 Hz - 20 kHz unweighted

0.00003 %

Analog Inputs

Inputs

4 high quality inputs with Iso-Float ground isolation

Maximum input / digital reference

+26 dBu / +21 dBu

Sampling rate / Resolution

96 kHz / 24 bit

Input impedance balanced / unbalanced

20 / 10 kOhm

THD+N (typical at 1 kHz unweighted)

0.00022 %

THD+N (typical at 20 Hz and 20 kHz unweighted)

0.00033 %

Processing / Network

Lake / Dante

Number of amplifier channels

4

Total burst power all channels (share among channels with RPM)

20000W

Back panel Interface

Analog, 2-channel I/O (input + link)

4 x 3-pin XLR, electronically balanced

AES / EBU / I/O (input + link)

2 x 3-pin XLR

Output connectors

Neutrik speakON (1 x NLT8, 2 x NLT4) or 4 Binding Posts (pairs)

Auto 10/100, Auto Uplink

2 x RJ45 etherCON

Control and monitoring interface

Via Ethernet for Lake Controller software, or DLM (the 3rd party protocol)

Detachable mains cord

Neutrik PowerCon rated at 250V/32A

Cooling

Three fans, front-rear airflow, temperature controlled speed

Mains Power

Nominal voltage

100 - 240 Volt AC 45 - 66 Hz

Operating voltage

70-265 V AC

Mains wall plug

NEMA L5-30 "Twist lock" 125 V / 30 A, and CEE 7/7 "Schuko" 230 V / 16 A

Rack rail to rear panel

W: 483 mm (19"), H: 88 mm (2 U), D: 424 mm (16")

Weight

17 kg (37 lbs)

 

功能說明

 

  • 5000 W per channel @ 2.67 ohms
  • 4400 W per channel @ 4 ohms
  • 2U chassis weighing only 17 kg (37 lbs)
  • Class TD® output stage
  • Universal (70 - 265 V) Regulated Switch Mode Power Supply (R.SMPS™) works anywhere in the world
  • Power factor correction (PFC) helps maintain full output during extended power bursts
  • Copper-finned Intercooler® with transverse-mounted output devices
  • Comprehensive loudspeaker preset database
  • LoadSmart™ load verification
  • Dante™ low-latency digital network included as standard
  • Compatible with Lake LM Series, and Lab.gruppen PLM and D Series
  • Primary and secondary network connections
  • Digitally controlled and recallable “amplifier gain” adjustable in 0.1 dB steps
  • Digital output attenuation in 0.25 dB steps from -inf to 0 dB
  • Binding post or Neutrik® speakON® output connectors
  • Digitally implemented, zero-overshoot Inter-Sample
  • Voltage Peak Limiting (ISVPL) adjustable in 0.1 V steps from 17.8 to 194 V
  • Breaker Emulation Limiter (BEL) prevents mains tripping
  • Under-Voltage Limiting (UVL) enables continued operation with mains voltage sags as low as 65 V
  • High-Resolution daylight viewable LCD display
  • Moisture resistant silicone touchpad